К вопросу о подаче керосина в поток острого орошения основной ректификационной колонны установок АВТ
DOI:10.32758/2782-3040-2021-0-5-50-53
УДК 66.0
D.A. Volynets3, E.A. Chernyshova2, A.V. Tarasov1
(1Yaroslavl State Technical University, Yaroslavl; 2Gubkin Russian State University of Oil and Gas, Moscow; 3AO “Promfinstroy”, Moscow)
Keywords: Kerosene, gasoline, circulating reflux, distillation proportion, rectification.
Abstract. In this article the possibility of suppling the kerosene fraction into the live reflux line of the K-2 column of the atmospheric vacuum pipestill units is reviewed. According to the results of mathematical calculations in the Petro-SIM software, the fraction 140-240°С was determined as optimal for supplying into the top live reflux line of the K-2 column of the atmospheric vacuum pipestill unit. This action makes it possible to reduce the load on the condensing system of the K-2 column of the atmospheric vacuum pipestill units; the heat potential of the hotter kerosene flow also increases, both for heating oil and for generating low-pressure steam. The article describes the advantages of the method.